The Grid coupling consists of:
Torque
Basic HP Ratings
Max Bore
Vertical
Ratings
@ Varying RPM
Max
Size
in-lb
Nm
100
1200
1800
3600
in
mm
RPM
1020
460
52
0.73
8.50
13.10
26.30
1.125
27
6,000
1030
1,320
149
2.09
24.50
37.70
75.40
1.375
35
1040
2,200
249
3.49
40.80
62.80
126.00
1.625
44
1050
3,850
435
6.11
71.50
110.00
220.00
1.875
51
1060
6,050
683
9.60
112.00
173.00
346.00
2.125
57
1070
8,800
994
14.00
163.00
251.00
503.00
2.500
68
5,500
1080
18,150
2051
28.80
337.00
518.00
1,037.00
3.000
83
4,750
1090
33,000
3728
52.40
613.00
942.00
1,885.00
3.500
95
4,000
1100
55,550
6276
88.10
1,031.00
1,587.00
—
4.000
108
3,250
1110
82,500
9321
131.00
1,532.00
2,356.00
4.500
117
3,000
1120
121,000
13671
192.00
2,246.00
3,456.00
5.000
137
2,700
1130
176,000
19884
279.00
3,267.00
5,027.00
6.000
165
2,400
1140
253,000
28584
401.00
4,697.00
7,226.00
7.000
184
Max Installation
Max Operational
Normal
Misalignment (in)
Gap (in)
Parallel
Angular (X-Y)
10%
0.006
0.002
0.012
0.010
0.118
0.003
0.011
0.013
0.008
0.004
0.016
0.015
0.018
0.005
0.020
0.024
0.001
0.007
0.028
0.032
0.177
0.009
0.035
0.022
0.040
0.236
0.047
0.053